View Catalog Page and Ordering Info
Portable Pre-Filter
PF-240 |
Designed for use with compressors that discharge a large volume of oil and water. Ideal for use in humid climates.
|
Replacement Filters
|
![]() |
|
BB15 Series BB15-AW BB15-CW BB15-DW BB15-FKW |
Replacement particulate filter - Stage 1 Replacement coalescing filter - Stage 2 Replacement charcoal filter - Stage 3 Filter kit for BB15-CO series models Contain 1 ea. "A", "C, and "D" replacement filter |
BB60 Series BB60-A BB60-C BB60-D BB60-FK |
Replacement particulate filter - Stage 1 Replacement coalescing filter - Stage 2 Replacement charcoal filter - Stage 3 Filter kit for BB60-CO series models Contain 1 ea. "A", "C, and "D" replacement filter |
|
BB30 Series BB30-A BB30-C BB30-D BB30-FK
|
Replacement particulate filter - Stage 1 Replacement coalescing filter - Stage 2 Replacement charcoal filter - Stage 3 Filter kit for BB30-CO series models Contain 1 ea. "A", "C, and "D" replacement filter |
BB50 Series BB50-A BB505-C BB50-D BB50-FK |
Replacement particulate filter - Stage 1 Replacement coalescing filter - Stage 2 Replacement charcoal filter - Stage 3 Filter kit for BB50-CO series models Contain 1 ea. "A", "C, and "D" replacement filter |
|
BB100 Series BB100-A BB100-C BB100-D BB100-FK |
Replacement particulate filter - Stage 1 Replacement coalescing filter - Stage 2 Replacement charcoal filter - Stage 3 Filter kit for BB100-CO series models Contain 1 ea. "A", "C, and "D" replacement filter |
BB75 Series
BB75-A BB75-C BB75-D BB75-FK |
Replacement particulate filter - Stage 1 Replacement coalescing filter - Stage 2 Replacement charcoal filter - Stage 3 Filter kit for BB75-CO series models Contain 1 ea. "A", "C, and "D" replacement filter |
View Catalog Page and Ordering Info
Air Systems' Carbon Monoxide/Oxygen Calibration kits are available in two sizes, 17 liter and 103 liter. The cylinders are disposable. All airline monitors should be calibrated on a monthly basis or if the accuracy of the monitor is in question. Use only Air Systems' gas concentration or an inaccurate calibration may occur.
|
BBK-20 17 Liter Cylinder |
BBK-20103 103 Liter Cylinder |
|
|
BBG-20 |

View Catalog Page and Ordering Info
Quick-Connect Couplings
٠Hansen٠Schrader٠Parker٠Snap-Tite٠National٠Perfecting٠CEJN٠Chicago٠Breco*Specify size and type when ordering breathing air systems and hoses
The couplings pictured above are the most popular styles used on airline respirators. A coupling, which is made up of a socket and a plug, is also called a “QD” or “fitting” and comes in various socket (female) and plug (male) sizes. Couplings can have male, female, or hose barb ends for different types of connection. Many manufacturers make interchangeable (equal) couplings that will fit another manufacturer’s style; most manufacturers make an interchange style of coupling that is compatible with other brands on the market. |
Breathing Air Hose
٠3/8", 1/2", 3/4" ID In Stock٠Specify desired coupling fitting size and length when ordering
HIGH PRESSURE HOSES ARE MADE TO ORDER UP TO 6000psi |
View Catalog Page and Ordering Info
|
Model HR-500MC |
Model HR-100M |
Model HR-50 |
View Catalog Page and Ordering Info
Remote Alarms
|
Remote Alarms act as a valuable early warning device for the isolated worker and allows him to make a safe egress when a system fault alarm occurs.
These remote alarm units have been designed to duplicate local alarms found on the primary equipment such as the Breather Box™, to signal workers in a remote location that there is an alarm condition with their system.
Note: Portable Breather Box® units require DC alarms. Wall mount filter panels require AC alarms.
|
|
Model 50-ALMST |
Model ALMSTH120 |
Models Available:
|
|
Innovation in Air DistributionSetting the Industry Standard inSafety Products for over 25 Years |
| A remote air manifold is often called a Point-of-Attachment (POA). All of our remote air manifolds meet NIOSH requirements of the 87-116 (1989) document for point-of-attachment. The Point-of-Attachment (POA) series provides remote manifold capability for respirator users, while complying with NIOSH regulations. The POA series consists of a regulator, pressure gauge, safety relief valve, and fitting congruency necessary for proper respirator operation. The POA box can be located any distance from the Grade-D filtration Breather Box® or filtration panel. The remote air manifold (POA) assembly becomes the NIOSH attachment point for the respirators and is now limited to a maximum of 300 feet of breathing air hose at the air outlet fitting on the remote POA box. |
Remote Air Manifolds
|
Specifications:
|
|
Using POA units, you can move the NIOSH point-of-attachment for airline respirators closer to the worker. |
![]() |
|
POA-XWM
Wall Mounted POA Manifold |
POA-4R
Independent Regulator POA Manifold |
POA-5RF
Independent Regulator POA Manifold |
|
Four independent regulators allow each worker to adjust their desired pressure depending on the style or respirator and length of hose. | Final filtration is added to remove water and particulates in plant air piping systems. |
Custom Designed POA Options
Portable CO Monitoring
|
| This portable airline monitor connects easily to a breathing air filtration source or ambient air pumps and monitors the air for CO content. The audible alarm (90dbA) and light will activate when the CO level exceeds 10ppm (5ppm Canadian). External alarm and lights allow for the unit to be used in the closed position and eliminates damage and contamination of the internal components. |
CO91-14LAC |
Specifications:
|
|
![]() |
Alarm set point is set at 10ppm in compliance with U.S. and International standards. Specify 5ppm for Canadian operation. |
View Catalog Page and Ordering Info
|
CO-91PM |
Panel Mounted CO Monitor
|
|
This durable carbon monoxide airline monitor panel can be ordered to retrofit any existing Grade-D breathing air system. It can be ordered with dual monitoring for CO and Oxygen (O2) content. Units supplied with high intensity audible alarm and 115 VAC power cord. All units are powder coated steel and are ready for wall mounting. Available in CSA approved Intrinsically safe version, 9 VDC only. |
CO/O2 Monitor |
|
CSA Approved Intrinsically Safe Monitor |