• All portable and fixed breathing air filtration systems meet or exceed OSHA 1910.134, Canadian Z180.1 Breathing Air Standards and British Standard
BS-EN 12021:1999 “RESPIRATORY PROTECTIVE DEVICES”

• All filtration units are designed to flow the NIOSH maximum capacity per worker

• Air Systems’ provides at NO CHARGE your first lab certified air quality test of your new breathing air filtration device.  Contact Customer Service for details.

Breather Box Family

Models: BB15-CO, BB30-CO, BB50-CO, BB100-CO
 
The Breather Box®
High Performance Portable Grade-D Breathing Air Filtration System

The Breather Box® is a portable Grade-D filtration system designed to provide breathing air for a specific number of workers.   The system filters incoming air from a compressor to provide ­respirator users with Grade-D quality air and ­monitors for CO and/or Oxygen.

The first stage element filters bulk water and particulate and has an auto drain.  The second stage coalescing filter eliminates atomized oils, mists, ultra-fine particulates, and has an auto drain.  The third stage filter removes organic vapors and odors and has a manual drain.  Filter change indicators are standard on all three stages of filtration.  Filtration efficiency is 99.99% @ .01 micron.  All Breather Boxes®  are designed to be used in the upright and closed position to prevent internal contamination.

The standard carbon monoxide (CO) airline monitor operates on disposable 9-volt batteries, 8-16 volt DC, or 115 VAC for continuous air monitoring.  An external audible alarm and light signals the workers of high CO content.  A remote alarm jack is provided on all models except for Model BB15-CO.  Point-of-Attachment (POA) boxes can extend respirator usage beyond 300 feet.

 

  

bb30_LR

 Custom Designed Breather Box® Options 

  • Clear View Windows
  • Independent Regulators to allow different respirators and lengths of hoses to be used simultaneously
  • Fully Automated Reserve Air Systems
  • Low Pressure Alarms

Contact Customer Service for Details

 

View Ordering Info

 

 

Typical Elements of a Breathing Air System

 Elements1

  Compressor                  Grade-D Filtration            Air Distribution(POA)       Respirator

The above pictured items make up a typical Grade-D breathing air system. Depending on the number of workers to be served by the system and whether the system needs to be portable or a fixed plant system, the size and complexity of the system may change. However, the basic elements above must be present. In order to properly size the breathing air system, it is absolutely essential that the user’s first decision is to decide the type and quantity of airline respirator(s) to be used. A quick recap of the airline respirator types and their required flow and pressure requirements is essential. All airline respirators are referred to by NIOSH as Type-C or Type-CE respirators. NIOSH approved CE respirators are designed for abrasive blasting but still require the same air flow as Type-C respirators.

 

Auto-Air™ Cart

View Catalog Page

View Ordering Info

View/Download the User Manual

Cart work

The Auto-Air™ Cart

The Auto-Air™ Cart provides a systems approach to breathing air filtration.  One cart contains our Grade-D filtration unit, and either a pneumatic or electric reserve air system and twin air cylinder storage.  Choose a cart size based on the desired amount of reserve air needed to allow workers to safely egress the work area.  Carts can operate with either 2400 or 5000psi cylinders. The pneumatic version should be selected for hazardous environments. 

 B10023HTAP
System mounted on 2300 series large cylinder cart

Model B10023HTAP

 

auto-air ergoThe custom Auto-Air™ Cart, pictured left, utilizes our Ergo-Air® Cart frame. The unit holds two large storage air cylinders and provides ease of mobility for use in plant air operations. Any size Auto-Air™ Breather Box® can be added to the Ergo-Air® Cart frame.

  

Consult Customer Service to Design a Cart to Meet Your Application

Intrinsically Safe Auto-Air™ Cart
Complete Pneumatic Operation

Note: Intrinsically Safe (IS) CO Monitors are CSA Approved for Class I, Division 1, Groups C and D Environments. Units are "DC" (9-Volt) Operation Only 

Applications

  • Refineries
  • Chemical and Pharmaceutical manufacturing
  • Refueling applications
  • Tank cleaning
  • Decon required situations
  • Grain silo entry

All lights and remote alarms are pneumatically operated and spark free. The intrinsically safe CO monitor is CSA approved and operates on 9-volt DC batteries only.


aacart
 
The Auto-Air™ Cart

Standard Electric Model

Applications

  • Confined space entry
  • Hazardous material handling
  • Boiler cleaning operations
  • Nuclear work
  • Fuel cell maintenance
  • Tank entry and cleaning

 

All HTAA Series Standard Carts Hold Two 87 or 60CF Air Cylinders.

Large Cylinder Carts Pictured are for Long Duration Applications.

 

System mounted on small cylinder cart

Model BB50-HTAA

 

 

Breathing Air Accessories

View Catalog Page and Ordering Info

Portable Pre-Filter

PF-240

PF-240

Designed for use with compressors that discharge a large volume of oil and water. Ideal for use in humid climates.

  • High capacity 300cfm bulk filtration and moisture removal - 200psi rated with metal bowl
  • Automatic drain assembly
  • Use after compressor and before Grade-D Breather Box® filtration unit
  • Galvanized steel frame with carry handle
  • Supplied with 1/2" Chicago fitting on inlet, 1/2" industrial interchange socket on outlet

View Catalog Page

Replacement Filters
for Breather Boxes® and Filtration Panels

Did You Know

In order to maintain Grade-D air quality, filters must be changed on a regular basis

Filter Replacement

BB15 Series

BB15-AW

BB15-CW

BB15-DW

BB15-FKW

 

Replacement particulate filter - Stage 1

Replacement coalescing filter - Stage 2

Replacement charcoal filter - Stage 3

Filter kit for BB15-CO series models

Contain 1 ea. "A", "C, and "D" replacement filter

BB50 Series

BB50-A

BB50-C

BB50-D

BB50-FK

 

Replacement particulate filter - Stage 1

Replacement coalescing filter - Stage 2

Replacement charcoal filter - Stage 3

Filter kit for BB50-CO series models

Contain 1 ea. "A", "C, and "D" replacement filter

BB30 Series

BB30-A

BB30-C

BB30-D

BB30-FK

 

 

Replacement particulate filter - Stage 1

Replacement coalescing filter - Stage 2

Replacement charcoal filter - Stage 3

Filter kit for BB30-CO series models

Contain 1 ea. "A", "C, and "D" replacement filter

BB75 Series

BB75-A

BB75-C

BB75-D

BB75-FK

 

Replacement particulate filter - Stage 1

Replacement coalescing filter - Stage 2

Replacement charcoal filter - Stage 3

Filter kit for BB75-CO series models

Contain 1 ea. "A", "C, and "D" replacement filter

BB100 Series

BB100-A

BB100-C

BB100-D

BB100-FK

 

Replacement particulate filter - Stage 1

Replacement coalescing filter - Stage 2

Replacement charcoal filter - Stage 3

Filter kit for BB100-CO series models

Contain 1 ea. "A", "C, and "D" replacement filter


View Catalog Page and Ordering Info

Airline Monitor Calibration Kits

Air Systems' Carbon Monoxide/Oxygen Calibration kits are available in two sizes, 17 liter and 103 liter.  The cylinders are disposable.  All airline monitors should be calibrated on a monthly basis or if the accuracy of the monitor is in question. Use only Air Systems' gas concentration or an inaccurate calibration may occur.

BBK-20

BBK-20

17 Liter Cylinder

BBK-20103

BBK-20103

103 Liter Cylinder

 

Use only Genuine Air Systems Calibration Gas when replacing cylinders

Zero Air Calibration GasBBG-00

 CO 20 ppm Calibration GasBBG-20

Prop 65 Warning CO


View Catalog Page and Ordering Info 

QUICK-CONNECT COUPLINGS 
٠Hansen٠Schrader٠Parker٠Snap-Tite٠National٠Perfecting٠CEJN٠Chicago٠Breco
*Specify size and type when ordering breathing air systems and hoses

Coupling Selection

The couplings pictured above are the most popular styles used on airline respirators.  A coupling, which is made up of a socket and a plug, is also called a “QD” or “fitting” and comes in various socket (female) and plug (male) sizes.  Couplings can have male, female, or hose barb ends for different types of connection.  Many manufacturers make interchangeable (equal) couplings that will fit another manufacturer’s style; most manufacturers make an interchange style of coupling that is compatible with other brands on the market. 

BREATHING AIR HOSE
٠3/8", 1/2", 3/4" ID In Stock
٠Specify desired coupling fitting size and length when ordering

air hose

HIGH PRESSURE HOSES ARE MADE TO ORDER UP TO 6000psi
CONTACT CUSTOMER SERVICE FOR DETAILS

               Fittings 101


View Catalog Page and Ordering Info

Breathing Air Hose Reels

Breathing air hose must be ordered separately.  All reels can be supplied with hose installed.  
Hose reels can be mounted on roller carts.
THERE ARE MANY CUSTOM OPTIONS AVAILABLE.  CONSULT OUR CUSTOMER SERVICE 
DEPARTMENT WITH YOUR REQUIREMENTS.

HR500MC

Model HR-500MC
Manual Hose Reel Cart with Fold Down Handle

HR-100M

Model HR-100M
Manual Hose Reel

HR-70

Model HR-50
Automatic Hose Reel


View Catalog Page and Ordering Info

Remote Alarms

50-ALMST

Remote Alarms act as a valuable early warning device for the isolated worker and allows him to make a safe egress when a system fault alarm occurs.
These remote alarm units have been designed to duplicate local alarms found on the primary equipment such as the Breather Box™, to signal workers in a remote location that there is an alarm condition with their system.
 
Note:  Portable Breather Box® units require DC alarms.  Wall mount filter panels require AC alarms.   
 

50-ALMST

Model 50-ALMST
DC Audible Alarm with Mounted Visual Strobe

ALMSTH120

Model ALMSTH120
AC Remote Audible/Visual Strobe with
Conduit Box

Models Available:

  • Standard audible, alarm, 90dbA
  • High intensity audible, 123dbA
  • Audible and visual combination units
  • Explosion-proof alarm
  • Wall mount alarm

Panel Mounted Systems

View Catalog Page

View Ordering Info

View/Download the User Manual

BACHP90

Breathing Air Panels for Permanent Mounting Applications

Permanent mount Grade-D filtration systems are designed to provide breathing air for a specific number of workers.  The system filters compressor air to provide respirator users with Grade-D quality air.  The first stage element filters bulk water and particulate, the second stage coalescing filter removes atomized oils and ultra-fine particulate, and the third stage removes organic vapors and odors.  Filter change indicators are standard on all three filtration stages.  Filtration efficiency is 99.99% @ .01 microns.  A built-in carbon monoxide monitor operates on 9-volt DC, 115 VAC, or 8-16 VDC for continuous detection.  A high intensity audible alarm and light signals the workers of high CO content in their breathing air.  A 115 VAC electrical conduit box is provided as standard to provide AC power in and connection for AC powered remote alarms.  Filtration components are mounted on powder coated steel panel.

did-you

All portable and fixed breathing air filtration systems meet or exceed OSHA 1910.134, Canadian Z180.1 Breathing Air Standards and British Standard BS-EN12021:1999 "Respiratory Protective Devices"

Air Systems' provides at NO Charge your first lab certified air quality test of your new breathing air filtration device. Contact Customer Service for details.

                    BB50-COPMBB50-COPM

15cfm

BB15-COPM 15cfm
Single Worker Grade-D Filtration
16"W x 14.5"H x 5.25"D

CSA

Intrinsically Safe CSA Approved Models Available for Class 1, Division 1, Groups C and D Environments.  Units are "DC" (9-Volt) Operation Only.

BB30-COPM

BB30-COPM
30cfm Two Worker Grade-D Filtration

Custom Panel Sizes are Available Up to 3000cfm Capacity!

1200

1200cfm Custom Breathing Air Panel

 

Auto-Air

Filtration

Fire/RescueVentilationPortable LightingCustom ProductsVentilation

Innovation in Air Distribution

Setting the Industry Standard in